Q11. What do you check during daily, weekly and monthly motor preventive maintenance?

Answer: Routine motor preventive maintenance covers operating condition, cooling, mounting and records at the intervals set by the site. Record phase current in amperes, bearing temperature in °C and applicable vibration in mm/s RMS at comparable load. Escalate a rising temperature or vibration trend before waiting for the next weekly or monthly round.

Read detailed article
12

Q12. How do you maintain motor bearings and choose the right grease and quantity?

Answer: Maintain motor bearings using the grease type, amount and interval specified for the installed bearing and motor. Regreasing instructions normally specify grams per bearing and operating hours, with shorter intervals possible at higher speed or temperature. Confirm grease compatibility and record the amount applied so repeated overgreasing can be identified.

Read detailed article
13

Q13. How do you inspect and tighten motor terminal connections?

Answer: Motor terminals should be examined for looseness, discolouration and damage during an authorised isolation. Tighten only to the manufacturer’s torque in N·m with a suitable torque tool, as the value depends on the terminal and fastener. Investigate heat marks or a damaged lug before tightening and returning the motor to service.

Read detailed article
14

Q14. Why must you clean the motor cooling fan, air inlet and cooling fins?

Answer: A clean fan, inlet and fin surface lets the motor discharge heat and maintain its intended temperature under load. On an IC411 motor, shaft-driven external airflow cools the frame, so blocked fins can raise temperature without a corresponding rise in current. After approved isolation, inspect the fan cover and compare running temperatures with the previous baseline.

Read detailed article
15

Q15. How do you check motor alignment and coupling condition?

Answer: Check motor and driven-shaft alignment and inspect the coupling for wear, damage and loose fasteners while safely isolated. Measure offset and angular error using a laser or dial indicator and compare with the coupling maker’s limits for the running speed. Check soft foot and record the alignment before and after tightening the mounting bolts.

Read detailed article
16

Q16. How do you prepare a lubrication schedule and interpret bearing noise?

Answer: A lubrication schedule lists bearing type, grease, quantity and service interval, while abnormal bearing noise prompts a condition check. Use the maker’s interval in operating hours and record temperatures and vibration against the normal baseline. If noise rises after greasing, check application records and operating conditions before assuming the bearing needs more grease.

Read detailed article
17

Q17. How do preventive and breakdown maintenance differ?

Answer: Preventive maintenance is planned work to reduce failures, while breakdown maintenance restores equipment after an unexpected fault. Preventive intervals can be based on calendar time or running hours, and breakdown performance can be tracked using repair time and downtime. Use failure history to adjust the preventive schedule where the same fault keeps recurring.

Read detailed article
18

Q18. What work is done during annual or shutdown maintenance of a motor?

Answer: Shutdown maintenance gives access for a closer inspection of windings, terminals, bearings, cooling parts and the drive connection. Record insulation resistance with test voltage and temperature, check alignment against the maker’s tolerance and compare results against the previous shutdown. Resolve failed checks before authorising restart and record the post-start baseline.

Read detailed article
19

Q19. How do you inspect motor cable glands and terminal-box seals during PPM?

Answer: Motor cable glands and terminal-box seals keep cable entries secure and help retain the specified enclosure protection. An IP55 terminal box depends on compatible glands, intact seals and correctly fitted blanks in unused entries. During isolated inspection, look for cracked gaskets, loose glands and water tracks before refitting covers to the maker’s instructions.

Read detailed article
20

Q20. How do you check motor foundation bolts, base plate and anti-vibration pads?

Answer: Inspect foundation bolts, base plate and resilient pads for movement, damage or uneven seating during planned maintenance. Compare bolt torque with the specified N·m value and review vibration in mm/s RMS under comparable load before and after corrective work. Check soft foot and pad condition if vibration returns after tightening or alignment.

Read detailed article

Test Your Knowledge Through Mock Test

Motor Practical – Part 2 · Two tests, 10 questions each. Choose a test below to begin.

Question 1 of 100 / 10 answered

Your answers stay on this page.

KEEP LEARNING WITH ELECTRICAL TOPIC

Learn Faster. Improve Your Electrical Skills.

WEBSITE • EMAIL UPDATES

New guides. Straight to your inbox.

Subscribe free. Get fresh website updates.

Have a question? Email info@electricaltopic.com

Videos in Hindi

Electrical Topic on YouTube

Watch practical electrical lessons from our YouTube channel.

Visit channel